Basic setting of auxiliary heater |
Note t
| Function “088” is not available at present for this auxiliary heater (used at the factory for initial filling of the fuel pipe). The “pipe filling” function and checking of the fuel delivery of the metering pump -V54- are to be implemented by way of display group “077”. |
t
| For this auxiliary heater, the “Auxiliary heater battery adaption” function is to be implemented by way of the “Adaption” function. |
t
| For the Audi A4, the hand transmitter of the auxiliary heater remote control is adapted by way of adaption function “10”. |
The following processes can be selected in the “Basic setting” function. |
t
| Pipe filling (display group number “077”) |
–
| This function can be used to check the fuel delivery of the metering pump -V54- → Chapter. |
t
| “Heater on” in normal operating mode (display group number “011”) → Chapter |
Note t
| If the link with the fault reader is lost with the auxiliary heater switched on, the auxiliary heater control unit -J364- automatically switches off the auxiliary heater. |
t
| In the case of an auxiliary heater with no circulation pump -V55- (version as supplementary heater, introduction not yet finalised), the engine is to be started before selecting this display group. |
t
| “Heater on” in operating mode “Test” (display group number “022”) → Chapter |
Note t
| This function can be used to operate the auxiliary heater up to a coolant temperature of 110 °C. Starting from control interval is possible. The operating time is limited to max. 10 minutes. |
t
| Further notes (as display group number “011”) → Chapter |
t
| “Heater off”(display group number “033”) → Chapter |
|
|
|