audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Renewing exhaust camshaft oil seal > < Renewing valve stem oil seals with cylinder head removed
Checking valve guides
Checking valve guides
Special tools and workshop equipment required
   
t  Universal dial gauge bracket -VW 387-
  W00-0037
t  Dial gauge -VAS 6079-
Test sequence
  W00-1261
–  Insert valve into guide. Valve stem end must be flush with guide. Only insert inlet valve into inlet guide and exhaust valve into exhaust guide, as the stem diameters are different.
–  Measure the amount of sideways play.
Wear limit
  V15-0133
Inlet valve guideExhaust valve guide
0.80 mm0.80 mm

  Note
t  If the wear limit is exceeded, repeat the measurement with new valves. Renew cylinder head if wear limit is still exceeded.
t  If the valve has to be renewed as part of a repair, use a new valve for the measurement.
   

Renewing exhaust camshaft oil seal > < Renewing valve stem oil seals with cylinder head removed