| Unplug electrical connector. |
–
| Unbolt pressure sensor from bulkhead. |
–
| Identify hoses on exhaust gas pressure sensor 1 -G450--item 1- for re-installation. |
–
| Release hose clips and spray both hoses with silicone-free lubricant. |
–
| Carefully disconnect the hoses from their connections (take care to keep the hoses straight: the connections can break off easily). |
Installation is carried out in the reverse order; note the following: |
Note Secure all hose connections with the correct type of hose clips (same as original equipment) → Parts catalogue. |
–
| Blow through hoses (towards particulate filter) with compressed air. |
–
| Connect hoses to exhaust gas pressure sensor 1 -G450- according to markings made earlier. |
|
|
|