Removing and installing mechanical exhaust gas recirculation valve > < Exhaust gas recirculation system
Exhaust gas recirculation system - exploded view
   
Exhaust gas recirculation system - exploded view
1 - Connecting pipe for exhaust gas recirculation
2 - Gasket
q   Renew
3 - 25 Nm
4 - Vacuum hose
5 - Bracket for exhaust gas recirculation cooler
q   With connection for coolant hose
6 - O-ring
q   Renew
7 - 9 Nm
8 - Coolant hose
9 - 9 Nm
10 - Exhaust gas recirculation cooler
q   Removing and installing → Chapter
11 - Coolant hose
12 - Coolant hose
13 - Gasket
q   Renew
14 - Vacuum hose
q   From exhaust gas recirculation cooler change-over valve -N345-
15 - Vacuum unit for exhaust gas recirculation changeover function
16 - 4 Nm
17 - Gasket
q   Renew
18 - 25 Nm
19 - Connecting pipe for exhaust gas recirculation
20 - Change-over flap for exhaust gas recirculation cooler
21 - Coolant hose
22 - 9 Nm
23 - Connection for coolant hose
24 - O-ring
q   Renew
25 - 9 Nm
26 - 9 Nm
27 - Bracket for change-over flap for exhaust gas recirculation cooler
28 - 9 Nm
29 - Gasket
q   Renew
30 - Mechanical exhaust gas recirculation valve
q   Removing and installing → Chapter
31 - 9 Nm

   

Removing and installing mechanical exhaust gas recirculation valve > < Exhaust gas recirculation system