Measuring radial clearance of conrods |
Special tools and workshop equipment required |
–
| Remove conrod bearing caps. |
–
| Clean bearing caps and bearing journals. |
–
| Place Plastigage onto bearing journal or into bearing shells corresponding to width of bearing. |
–
| Fit conrod bearing cap and tighten to 40 Nm, but do not turn further. Do not rotate crankshaft. |
–
| Remove conrod bearing caps once more. |
–
| Compare width of Plastigage with measurement scale: |
l
| New: 0.020 ... 0.069 mm. |
–
| Renew bolts for conrod bearings. |
|
|
|