audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Removing air cleaner housing - vehicles with 6-cyl. petrol engine > < Removing air cleaner housing - vehicles with 1.8 ltr. turbo engine
Removing air cleaner housing - vehicles with 2.0 ltr. FSI engine
Removing air cleaner housing - vehicles with 2.0 ltr. FSI engine
   
Procedure
–  Detach cover (right-side) -1- in engine compartment.
  A10-1030
–  Unscrew bolts -arrows-.
–  Detach activated charcoal filter solenoid valve 1 -N80--item 1- at air duct.
–  Remove air duct -2-.
  A10-0900
–  Detach air intake hose -1- at air mass meter -G70-.
  Note
Disregard -item 2-.
  A15-0698
–  Unplug electrical connector -1- at air mass meter -G70-.
–  Pull off clip -2- and remove air cleaner housing together with air mass meter -G70-.
Installation is carried out in the reverse order; note the following:
  Note
Secure all hose connections with the correct type of hose clips (same as original equipment) → Parts catalogue.
–  Install air cleaner housing → Rep. Gr.24.
  A10-1404

Removing air cleaner housing - vehicles with 6-cyl. petrol engine > < Removing air cleaner housing - vehicles with 1.8 ltr. turbo engine