audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Determining location of fault > < Repairing aerial wires
Fibre optic cables
Fibre optic cables
  Caution
Risk of damage to fibre optic cables.
t  The fibre optic cables must not be severely kinked. Bending radius must not be less than 25 mm.
t  The fibre optic cables must not located over sharp edges.
t  The ends of the fibre optic cables must not be made dirty or touched with bare hands.
t  The fibre optic cables must not be heated.
t  Twisting two fibre optic cables or a fibre optic cable with a copper wire is not permitted.
t  Protect connector and connecting cable from dust. Use protective caps from set.
   

Determining location of fault > < Repairing aerial wires