A4 Mk3
| Exploded view - plenum chamber partition panel |

| 1 - | Bolt |
| q | 7 Nm |
| 2 - | Lock washer |
| q | When installing, only press on studs of plenum chamber partition panel. |
| 3 - | Insulation |
| q | Insulation secured to plenum chamber partition panel with lock washer |
| 4 - | Nut |
| q | 7 Nm |
| 5 - | Plenum chamber partition panel |
Note| When removing, pay attention to different versions. |
| q | Before removing: |
| – | Remove body brace → Rep. gr.40. |
| – | Detach washer fluid reservoir. |
| – | Detach vacuum line to brake servo unit at connection to plenum chamber partition panel. |
| – | Unclip vacuum line from plenum chamber partition panel. |
| q | To remove, unscrew bolts -1- and nut -4-. |
| 6 - | Seal |
| q | Push seal on from underneath. |
| 7 - | Plenum chamber |
| 8 - | Edge protection |
| q | Slide edge protection onto lug on plenum chamber partition panel. |