Place a cloth underneath bracket for ancillaries to catch any escaping oil. |
–
| Unplug electrical connector -3- at oil pressure switch for reduced oil pressure -F378-. |
–
| Unscrew oil pressure switch for reduced oil pressure -F378--4-. |
Installation is carried out in the reverse order; note the following: |
Note t
| Fit the new oil pressure switch for reduced oil pressure -F378- into the connection immediately to avoid loss of oil. |
|
|
|