audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Reducing agent metering system - vehicles with SCR catalytic converter > < Removing and installing exhaust gas recirculation cooler
Removing and installing exhaust gas recirculation temperature sensorG98
Removing and installing exhaust gas recirculation temperature sensor -G98-
   
Removing
–  Remove intake manifold → Rep. gr.23.
  A23-10532
–  Take electrical connector -1- out of bracket, unplug it and move electrical wiring clear.
–  Unscrew exhaust gas recirculation temperature sensor -G98--item 2-.
Installing
Installation is carried out in the reverse order; note the following:
l  Tightening torque → Chapter „Exhaust gas recirculation system - exploded view“
–  Install intake manifold → Rep. gr.23.
  A26-11012

Reducing agent metering system - vehicles with SCR catalytic converter > < Removing and installing exhaust gas recirculation cooler