Fitting location of Lambda probes on cylinder bank 2 (left-side) |
1 - | Lambda probe 2 -G108- with Lambda probe heater 2 -Z28- |
2 - | Lambda probe 2 after catalytic converter -G131- with Lambda probe 2 heater after catalytic converter -Z30- |
l
| Tightening torque: 55 Nm |
Note t
| New Lambda probes are coated with an assembly paste. |
t
| The assembly paste/high-temperature paste must not get into the slots on the Lambda probe body. |
t
| When installing, the Lambda probe wire must always be reattached at the same locations to prevent it from coming into contact with the exhaust pipe. |
t
| Fit all cable ties in the original positions when installing. |
Removing and installing Lambda probe -G39- and Lambda probe heater -Z19- → Chapter. |
Removing and installing Lambda probe after catalytic converter -G130- and Lambda probe 1 heater after catalytic converter -Z29- → Chapter |
Lambda probe 2 -G108- with Lambda probe heater 2 -Z28- → Chapter |
Lambda probe 2 after catalytic converter -G131- with Lambda probe 2 heater after catalytic converter -Z30- → Chapter |
|
|
|