| Hold this hose -1- in a suitable container -2- to measure the return flow rate. |
–
| Start engine and let it idle. |
l
| Specification: 100 ml (+/- 10 %) in 30 seconds |
If specification is not obtained, fuel pressure regulating valve -N276- is defective. |
If it is not possible to start engine, perform test at starter cranking speed. |
l
| Specification of return flow rate: 0 ml |
If specification is not obtained, fuel pressure regulating valve -N276- is defective. |
|
|
|