| Release catch -1-, turn cover for air cleaner housing in anti-clockwise direction -arrow A- and detach. |
–
| Take out air filter element. |
Installation is carried out in the reverse order; note the following: |
To ensure that the air mass meter -G70- functions properly, it is important to observe the following notes and instructions. |
Note t
| If the air filter element is very dirty or wet, dirt or water could reach the air mass meter and affect the air mass value. This would lead to loss of power, since a smaller injection quantity is calculated. |
t
| Always use genuine part for air filter element. |
t
| The air cleaner housing MUST be clean. |
t
| Hose connections and air pipes and hoses must be free of oil and grease before assembly. |
t
| To prevent malfunctions, cover critical parts of the engine air intake (air mass meter, air pipes, etc.) with a clean cloth when blowing out the air cleaner housing with compressed air. |
t
| Use a silicone-free lubricant when installing the air hoses. |
t
| To secure the air hoses at their connections, spray rust remover onto the worm thread of the used hose clips before installing. |
t
| Observe environmental requirements for disposal. |
|
|
|