Leak Detection Pump: Testing and Inspection
Leak Detection Pump, Checking

Leak Detection Pump, Checking

Special tools, testers and auxiliary items required

‹› Multimeter.

‹› Wiring diagram.

Test requirements

‹› The Leak Detection Pump (LDP) (V144) fuse OK.

‹› The ignition switched off.

Procedure

-

Remove the left rear wheel housing liner.

-

Disconnect the Leak Detection Pump (LDP) (V144 ) electrical harness connector - 2 -.

Checking internal resistance

-

Using a Multimeter, check the Leak Detection Pump (LDP) (V144) for resistance as follows: 