Remove horn connector - 6 -.
-
Place airbag unit - 5 - so padding faces upward.
‹› Installing:
To install, perform the steps used in removal in reverse order. Observe the following when doing so:
-
Ensure connector and securing clip engage completely (audibly).
-
Ensure no wires are in contact with gas generator.
-
Ensure airbag wiring is not kinked. Route airbag wiring in a loop to the left.
-
Route horn wiring in a loop toward outside.
-
Tighten bolts - 1 - (Qty. 2) to a tightening specification of 7 Nm.
-
Switch on ignition.
CAUTION!
No one should be in vehicle when connecting battery.
-
Connect the battery ground (GND) strap.
‹› Follow safety measures after connecting battery.
‹› If the Airbag Malfunction Indicator Lamp (MIL) ( K75) shows a malfunction after assembly, DTC memory must be checked with Vehicle
Diagnostic, Testing and Information System ( VAS 5051 A), cleared and then rechecked.
6
Horn Connector
7
Socket Head Bolt
‹› Tightening specification, refer to => Steering See: Steering and Suspension/Steering
8
Steering Wheel Heating Connector
9