‹› The higher the specified weight of the siphoned battery acid, the higher the float will float.

‹› The acid density of the electrolyte can be read off in kg/dm 3 on the hydrometer scale (specified density of the battery acid). 

-

Compare hydrometer reading to values given in table.

Specified acid density must be at least 1.24 kg/dm3 in moderate climate zones. If the acid density in all battery cells is too low: 

-

Charge battery and repeat acid density test.

-

If the specified values are not reached, replace battery.

‹› The measured values for the specific gravity of the individual battery cells must not deviate by more than 0.03 kg/dm3, otherwise the battery

should be replaced.