Battery: Component Tests and General Diagnostics
Battery, Load Testing With Midtronics Diagnostic Conductance Charging Station INC-940

Battery, Load Testing With Midtronics Diagnostic Conductance Charging Station INC-940

The Midtronics Diagnostic Conductance Charging Station INC-940 (also known as "inCHARGE 940") integrates battery conductance and load testing
with charging.

By checking a batteries current draw capacity during charging, a decision can be made as to whether a severely discharged battery can be made usable
again by recharging, or if it must be replaced.

CAUTION:

Risk of injury from battery acid.
-

Prior to handling or servicing batteries, read, understand and observe the Warnings and Safety Measures for lead-acid batteries for
lead-acid batteries

-

Wear protective eye wear and clothing.

-

On non-maintenance-free batteries, the sealing plugs must be installed tightly.

-

Provide sufficient ventilation.

-

If the magic eye has no color or is light yellow, the battery may not be tested or charged. Jump starting must not be used: There is a risk
of explosion during testing, charging or jump starting. The battery must be replaced.

-

DO NOT battery test batteries which are gassing. Otherwise there is a risk of explosion.

-

Rapid-charging batteries.

-

Dispose of electrolyte (sulfuric acid/water mixture) properly: Waste electrolyte must only be disposed of in appropriate waste disposal
sites. Refer to local regulations pertaining to electrolyte disposal.

-

The following notes and procedures must be followed to ensure correct measurements.

Risk of damaging AGM batteries.
-

Specific charging procedures are required for AGM batteries.

Special tools, testers and auxiliary items required

-

Midtronics Diagnostic Conductance Charging Station INC-940 (VAS tester illustrated here for reference only)

Prerequisite
Battery temperature must be at least +10 degrees C.

Procedure

CAUTION:

-

Switch off all electrical consumers.

-

Switch ignition off and remove ignition key.

-

Refer to Midtronics Diagnostic Conductance Charging Station INC-940 Instruction Manual.

-

Perform any model-specific preparations necessary to gain access to battery terminals or battery jump-start terminals.

-

Connect tester cable clamps to battery terminals INC-940 Instruction Manual. Tester leads must be securely fastened and make proper contact with
battery posts.

-

Select charge mode "Automatic" INC-940 Instruction Manual

-

Select test mode "IN-VEHICLE" or "OUT-OF-VEHICLE" as appropriate INC-940 Instruction Manual.

-

Select battery type (AGM or conventional) INC-940 Instruction Manual

-

Set tester to "Warranty Test" INC-940 Instruction Manual.

-

Select battery DIN rating value as appropriate INC-940 Instruction Manual.

NOTE:  Use the "Generate Test Code" function of INC-940 in event test results are required for warranty claims.