Battery: Component Tests and General Diagnostics
Battery - Vehicles With Energy Management Control Module, Testing With Vehicle Diagnosis Using
System VAS 5051B

Battery Testing

Maintenance-free batteries must not be opened. Otherwise, the warranty is void.

Battery - Vehicles with Energy Management Control Module, Testing with Vehicle Diagnosis, Testing and Information System VAS 5051B

Special tools, testers and auxiliary items required

‹› e.g. Vehicle Diagnosis, Testing and Information System (VAS 5051B) (or any of the (VAS 505X) class testers) with diagnostic cable

Prerequisites

‹› Battery must not be in process of being charged.

‹› Engine must not be running.

‹› Battery temperature must be at least -10 °C.

‹› Diagnostic system temperature must be between +5 and 45 °C.

Procedure

-

Connect Vehicle Diagnosis, Testing and Information System (VAS 5051B) => [ Vehicle Diagnosis, Testing and Information System VAS 5051B,
Connecting ] See: Power and Ground Distribution/Wiring Harness/Description and Operation.

‹› If an error message appears on the display => , (VAS 5051B) operating instructions.

-

Press Guided Functions button on operating mode selection screen.

Display:

-

Enter vehicle identification number (VIN) in field - 1 - in selection - A -.

The Vehicle Diagnosis, Testing and Information System (VAS 5051B) then switches to the next selection level. The following example shows how
vehicle type, engine and vehicle system of function could be selected (some steps may be skipped):

The following information is given as an example only. Always enter required information as it pertains to vehicle being serviced. 

Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 7575 > < Battery, Testing With Midtronics Battery/Starting/Charging System Analyzer MCR340A|Page 7573