A4 Quattro Sedan V6-3.0L (AVK) (2002)
Indicated on display
Rapid data transfer
HELP
Select function XX
-
Press -1- and -0- and confirm by pressing the -Q- button.
Indicated on display
Rapid data transfer
Q
10 - Adaptation
-
Press -Q- button to confirm input.
Indicated on display
Adaptation
Input Channel number XX
-
Press buttons -0- and -3-.
-
Press -Q- button to confirm input.
NOTE:
-
Adaptation only for vehicles with on board computer.
-
Value entered must be between 85% and 115%.
-
Value must be entered in steps of 5%.
-
If the value "100" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.
Indicated on display:
Channel 3 Adaptation 100
->
Consumption display < -1 3- >
-
Press -> button.
NOTE: Correction of fuel consumption display is only possible via direct input.
Indicated on display:
Channel 3 Adaptation 100
Input adaptation value XXXXX
-
Input desired correction value using scan tool keypad, filling initial positions with "0".
Example:
Desired input value: 90%
Keypad input: 00090
Indicated on display:
Channel 3 Adaptation 100
Q
Input adaptation value 00090
-
Press -Q- button to confirm input.
Indicated on display:
Channel 3 Adaptation 90
Q
Consumption display < -13- >
-
Press -Q- button to confirm input.
Indicated on display: