A4 Quattro Wagon L4-1.8L Turbo (ATW) (2000)
-
Angle position, cover flange to inner section of surge housing: 10°
-
Press together clamps for supply line (between pump and cover flange) with VAG1275 pliers.
-
Attach wiring to fuel pump.
-
M4: 1.5 Nm
-
M5: 2 Nm
NOTE: Install a toothed washer beneath each nut.
-
Attach wiring with fuel-resistant cable ties.
Installing
Installation is performed in the reverse of removal, when installing, note the following:
CAUTION!
Always refer to the latest parts catalog to ensure that you use original equipment fuel hose clamps.
-
Install surge housing inner section, supply hose and cover flange in the fuel tank.
-
Place inner section of surge housing into outer section of surge housing in tank such that notch -1- on inner section of surge housing matches mark
-2- on outer section of surge housing.
-
The inner section of the surge housing can be audibly pressed downward.
-
Attach 3307 pump wrench and turn surge housing inner section to the right approx. 15° (up to the stop).
-
Notch -1- will then be in front of mark -3- (bayonet closure)
NOTE: For clarity, the surge housing outer and inner sections are shown in the illustration without the fuel tank.