audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Exhaust Turbocharger Vacuum Diaphragm, Checking|Page 7103 > < Exhaust Turbocharger Vacuum Diaphragm, Checking|Page 7101
Page 3
background image

-

Connect hand vacuum pump VAS 6213 , turbocharger tester V.A.G 1397A to connection II and pressure regulator valve VAS 6342 as depicted in
the illustration.

-

Close Pressure Control Valve VAS 6342 on lever - 1 - .

-

Adjust slide ring - 1 - on Hand Vacuum Pump VAS 6213 to - B - position for "Pressure".

-

Switch on Turbocharger Tester V.A.G 1397A and adjust slide switch to position II.

-

Secure Dial Gauge Holder VW 387 on turbocharger - arrow - .

NOTE:  The mm specifications apply to the value read out (includes 1 mm pre-load).

-

Secure Dial Gauge 0-30 mm VAS 6341/1 with Dial Gauge Extension, 30 mm VAS 6341/3 and Flat Pickup VAS 6341/4 to Dial Gauge Holder
VW 387.

-

Set Dial Gauge 0-30 mm VAS 6341/1 to 1 mm pre-load with 0 bar on vacuum diaphragm.

Exhaust Turbocharger Vacuum Diaphragm, Checking|Page 7103 > < Exhaust Turbocharger Vacuum Diaphragm, Checking|Page 7101