Battery: Service and Repair
Battery, Charging
Battery, Charging
CAUTION:
-
Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.
-
Always wear suitable protective clothing.
Danger of explosion.
-
Batteries produce explosive gasses while being charged.
-
Keep open flames and sparks away and DO NOT smoke near batteries.
-
The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.
-
Battery cell caps must NOT be removed while charging.
-
"Boosting" a sulfated battery a high charging rate can cause an explosion.
-
Ensure that battery is charged in a well ventilated area.
-
Precision tools must not be kept in the same room where batteries are being charged. Tools may corrode due to chemical reaction.
Special tools, testers and auxiliary items required
-
Battery Charging Station: Midtronics INC-940.
NOTE:
-
Before charging, battery must have a minimum temperature of 10 degrees Celsius (50 degrees Fahrenheit).
-
It is not necessary to remove battery from vehicle or disconnect battery terminals.
-
Charging voltage must not exceed 14.4V.
-
Always follow the battery charger operating instructions.
-
After charging, confirm battery no load voltage and electrolyte specific gravity before reuse in vehicle.
CAUTION:
Before beginning repairs on electrical system
-
Switch off all electrical consumers.
-
Switch ignition off and remove ignition key.
-
Slide battery cover to right - arrow 1- and lift off - arrow 2- where applicable.
-
Connect battery charger to battery, positive to positive ( + ) - 2 -, negative to negative (-) -1
-
Switch on battery charger.
CAUTION: If battery begins gassing (boiling) violently when charging, REDUCE charging rate immediately.