Battery: Service and Repair
Battery, Charging

Battery, Charging

CAUTION:

-

Prior to handling or servicing batteries, read, understand and observe the Warning and Safety Measures for lead-acid batteries.

-

Always wear suitable protective clothing.
Danger of explosion.

-

Batteries produce explosive gasses while being charged.

-

Keep open flames and sparks away and DO NOT smoke near batteries.

-

The battery charger MUST be turned off when connecting or disconnecting the cables at the battery.

-

Battery cell caps must NOT be removed while charging.

-

"Boosting" a sulfated battery a high charging rate can cause an explosion.

-

Ensure that battery is charged in a well ventilated area.

-

Precision tools must not be kept in the same room where batteries are being charged. Tools may corrode due to chemical reaction.

Special tools, testers and auxiliary items required

-

Battery Charging Station: Midtronics INC-940.

NOTE:

-

Before charging, battery must have a minimum temperature of 10 degrees Celsius (50 degrees Fahrenheit).

-

It is not necessary to remove battery from vehicle or disconnect battery terminals.

-

Charging voltage must not exceed 14.4V.

-

Always follow the battery charger operating instructions.

-

After charging, confirm battery no load voltage and electrolyte specific gravity before reuse in vehicle.

CAUTION:

Before beginning repairs on electrical system

-

Switch off all electrical consumers.

-

Switch ignition off and remove ignition key.

-

Slide battery cover to right - arrow 1- and lift off - arrow 2- where applicable.

-

Connect battery charger to battery, positive to positive ( + ) - 2 -, negative to negative (-) -1

-

Switch on battery charger.

CAUTION:  If battery begins gassing (boiling) violently when charging, REDUCE charging rate immediately.

Warnings and Safety Measures For Lead-Acid Batteries|Page 9618 > < Warnings and Safety Measures For Lead-Acid Batteries|Page 9616