Air Door Actuator / Motor: Removal and Replacement
Defroster Door Motor

Defroster Door Motor

‹› On this vehicle, all control motors are currently identical. During the basic adjustment, the control motors are assigned and adapted corresponding

to the switching sequence of the wiring. If this sequence does not conform the specification, the control motors will adapt incorrectly and the door
control will be wrong. Refer to => [ Climatronic Control Module ] See: Description and Operation/A/C System Control.

Removing

-

Move the driver seat as far back as possible.

-

Switch off ignition.

-

Remove the storage compartment under the dash panel on the driver's side.

-

Remove the left footwell (driver side). Refer to=> [ Left Footwell Door Motor ] See: Left Footwell Door Motor

-

Remove the accelerator pedal module. 

-

Mark the connector - D - if necessary (to rule out an interchange in the event several connectors are disconnected at the same time).

-

 Disconnect the connector - D -.

-

Remove the screws - C -.

‹› To remove the screw - C - use Ratchet Wrench (T40083).

-

Loosen the shaft - A - (on the motor - B -) from the actuating arm - E - and remove the motor.

Installing

Installation is carried out in the reverse order, when doing this note the following.

-

Check the position of the actuating arm - E - in the A/C guide - F - ; when doing this, pay attention to both stops - G -.

-

Insert the shaft - A - (on the motor - B -) into the actuating arm - E -.

‹› The control motor does not have a stop; therefore the shaft -  A - can be inserted into the actuating arm - E - in any position.

-

Install the screws - C -.

-

Connect the connector - D -.

-

Install the wiring harness so that it cannot come in contact with any moving parts (e.g. the actuating arm).