audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Pressure Sensor / Switch, HVAC > < Refrigerant Oil|Capacity Specifications|Page 9909
Page 1
background image

Refrigerant Oil: Service and Repair

A/C Refrigerant System

Capacities

-

Operate the A/C system after filling the refrigerant circuit. Refer to=> [ Operating A/C System after Filling Refrigerant Circuit ]. See: Description
and Operation/A/C Refrigerant System/Operating A/C System After Filling Refrigerant Circuit

‹› Note the information regarding operating the A/C system after filling, refer to Refrigerant R134a - Servicing.

‹› Depending on the allocation of the service connection an on the refrigerant line, and on the version of the vehicle, it may be necessary to remove

the additional reinforcement on the left suspension strut dome so that the service coupling of the service station can be connected (for example, on
the Audi Q5). Refer to and Heating/Ventilation/Air Conditioning; Air Conditioning with R134a refrigerant.

‹› Depending on time period of production and on engine, compressor construction type may vary.

‹› At start of production, compressors manufactured by "Denso" (type " 6 SEU 14") on 4 and 6 cylinder vehicles Engine and type "7 SEU 17" on

vehicles with 8 cylinders FSI engine) installed. Compressors from other manufacturers may also be installed at a later time.

‹› Depending on the type of compressor, different refrigerant oil capacities are intended for the refrigerant circuit.

‹› Compressor as replacement part has different oil fill capacities, therefore note the exact part number. The reason for the different oil capacities in

the compressor lies in the design of the compressor itself, note these oil capacities. Too much oil in the circuit leads to high pressures and to a
reduction in the system cooling performance, too little oil may lead to lubrication problems in the compressor.

‹› Always fill refrigerant circuit as far as upper tolerance limit (some refrigerant remains in filler hoses).

‹› Only add approved refrigerant oils to the refrigerant circuit.

‹› Zexel / Valeo, Sanden and Denso compressors require different refrigerant oils.

‹› Use only the specified oil from a sealed container and always reseal oil container immediately after use (PAG oil absorbs moisture). Do not use oil

if it is contaminated with moisture or if oil container has been left open.