A4 Quattro Wagon L4-2.0L Turbo (CAEB) (2009)
If the specified values were Not obtained:
-
Replace the Ambient Air Temperature Sensor (G17 ).
If the specified values are obtained, continue the test according to the following table:
Checking wiring
-
Turn the key on.
-
Connect a multimeter to terminals 1 and 2 of the Ambient Air Temperature Sensor (G17) electrical harness connector.
Specified value: near 5.02 V
If the specified value was Not obtained:
-
Turn the key off.
-
Remove the Instrument Cluster. Refer to the appropriate service manual.
-
Disconnect the Instrument Cluster harness.
-
Using a multimeter, check the Ambient Air Temperature Sensor (G17) electrical harness connector terminals 1 and 2 to the Instrument Cluster
electrical harness connector T36 for an open circuit or a short, refer to the appropriate wiring diagram.
Specified value: 1.5 ohms max.
If the specified value was obtained:
Replace the Instrument Cluster.
If the specified value was Not obtained:
-
Check the wiring for an open, high resistance or short circuit to Battery (+) or ground.
-
Check the electrical harness connector for damage, corrosion, loose or broken terminals.
-