A4 Sedan L4-1.8L Turbo (AWM) (2001)
-
To remove, unclip valve from side of filler-neck.
-
Lever in rest position: Valve closed
-
Lever pressed in direction of arrow: Valve open
Fig. 2 Ground connection installation position
-
Route Ground connection -arrow-, as shown in illustration.
-
Ensure tight fit of electrical Ground connection to fuel filler-neck Ground clamp.
-
Attach wiring terminal -1- with screw -2- for fuel filler-neck.
CAUTION! After installation, check for continuity between Ground clamp on filler neck and chassis Ground.
-
Specification: approximately 0 ohms