audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Checking ECM Voltage Supply|Page 5766 > < LED Test Light|Page 5762
Page 1
background image

Engine Control Module: Component Tests and General Diagnostics
Checking ECM Voltage Supply

REQUIREMENTS:

-

Fuse for ECM OK.

PROCEDURE:

-

Connect test box VAG 1598/19 to ECM wiring harness.

-

Switch ignition on.

-

Connect VAG 1527B voltage tester between test box socket D10 (B+) and Ground (GND).

Voltage Tester Must Light Up.

If voltage tester does not light up:
-

Check for open circuit using wiring diagram, and repair as necessary.

If voltage tester lights up:
-

Connect voltage tester between test box socket D10 (B+) and then in sequence to test box Ground (GND) sockets A19, D3, D7, D12, E3, E7 and
E11.

Voltage Tester Must Light Up.

If voltage tester does not light up:
-

Check wiring using wiring diagram and eliminate open circuit if necessary.

-

Connect VAG 1527B voltage tester between test box socket B10 (B+) and engine Ground (GND).

Voltage Tester Must Light Up.

If voltage tester does not light up:
-

Check wiring between ECM connector B terminal 10 and central electrical panel using wiring diagram and, if necessary, eliminate open circuit.

Checking ECM Voltage Supply|Page 5766 > < LED Test Light|Page 5762