audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

High Pressure Sensor / Switch, HVAC|Description and Operation|Page 971 > < High Pressure Sensor / Switch, HVAC|Description and Operation
Page 1
background image

High Pressure Sensor / Switch: Service and Repair

A/C Refrigerant System (R-134a) Switches & Sensors, Servicing (1996)

A/C Refrigerant High Pressure Switch -F23-/-F118-

Function:

High pressure switch -F23- (contacts -1- and -2- in switch -A-) switches coolant fan V7 into stage 2 (contacts -1- and -2- in connector -B-) when A/C
system pressure increases.

Switching pressures:

-

Fan stage 2 on (switch closes): 14.3 to 17.3 bar pressure

-

Fan stage 2 off (switch opens): 10.9 to 15.3 bar pressure

-

Pressure difference between switching points: 2.0 to 3.4 bar

High-pressure switch F118 (contacts -3- and - 4- in switch -A-) switches the compressor off via A/C control head E87 (contacts -3- and -4- in connector
-B-) if excess pressure exists in refrigerant system.

Switching pressures:

-

Compressor off (switch opens): 28.2 to 31.0 bar pressure

-

Compressor on (switch closes): 11.5 to 15.0 bar pressure

Removing and installing

-

Remove front bumper.

-

Disconnect electrical harness connector.

-

Replace O-ring seal -A-, 7.6 mm1.8 mm.
Tightening torque: 5 Nm (44 in lb)

High Pressure Sensor / Switch, HVAC|Description and Operation|Page 971 > < High Pressure Sensor / Switch, HVAC|Description and Operation