Recirculation Flap Motor V113, Removing And Installing
Recirculation Flap Motor V113, Removing And Installing
Removing
-
Remove glove compartment
-
Disconnect connector - A -.
-
Remove bolts - B -.
-
Pull connecting element - C - of Recirculation Flap Motor V113 out of recirculated-air flap shaft - D -.
Installing
NOTE: The control motor connecting element is color-coded; for the Recirculation Flap Motor V113 it is blue
Reinstall all parts removed in reverse order, paying attention to the following:
-
Lay wiring harness such that it cannot come into contact with moving components (e.g. control motor lever).
-
Check and erase DTC memory; perform basic setting.
NOTE: Operation of the control motor can be checked as follows: Connect the two contacts "5" and "6" in the control motor connector to a 12 V
DC source. The control motor moves as far as the stop in one direction. Interchanging positive and negative reverses direction. Use adapter for this
purpose.