Remove the central venting hose - arrow -.

-

Remove battery from plenum chamber.

CAUTION!
Pollution risk.

‹› Battery and sulfuric acid disposal regulations must be followed when disposing of batteries.

Installing

Install in reverse order of removal, observing the following:

‹› Only maintenance-free batteries conforming to standards "TL82506 " (as of December 1997) and "VW75073" (as of August 2001) may be

installed.

‹› Batteries from the Audi Parts Program have a bottom strip-adapter for adapting to different grip channels. Whether and how bottom strip-adapter

is used, refer to operating instructions for battery.

-

Insert battery into battery holder so that tab of rear battery holder -  arrow - engages into cutout for battery clamping strip -  -.

‹› It should no longer be possible to move the battery.

-

Battery is properly inserted when center notch of battery base reinforcement aligns with threaded hole in battery carrier - arrows -.