‹› Make sure plate contact surface fits exactly and is free of oil.

-

Remove master gauge and insert measuring tool into housing.

‹› The dial gauge faces toward final drive cover

-

Install cover for final drive and tighten 4 bolts to 20 Nm.

-

Using adjustable ring, pull 2nd centering pad ( VW 385/36) out as far as possible so that the measuring tool can still just be turned by hand.

-

Turn measuring tool until dial gauge point touches the end measuring plate on pinion shaft head, then measure maximum deflection (return point). 