A5
Lambda probes - overview |
Note
t | New Lambda probes are coated with an assembly paste. |
t | In the case of a used Lambda probe, coat only the thread with high-temperature paste; refer to → Electronic parts catalogue for high-temperature paste. |
t | The assembly paste / high-temperature paste must not make contact with the slots on the Lambda probe body. |
1 - | Lambda probe 2 after catalytic converter -G131- |
q | With Lambda probe 2 heater after catalytic converter -Z30- |
q | Removing and installing → Chapter |
q | 55 Nm |
2 - | Lambda probe 2 -G108- |
q | With Lambda probe heater 2 -Z28- |
q | Removing and installing → Chapter |
q | 55 Nm |
3 - | Lambda probe -G39- |
q | With Lambda probe heater -Z19- |
q | Removing and installing → Chapter |
q | 55 Nm |
4 - | Lambda probe after catalytic converter -G130- |
q | With Lambda probe 1 heater after catalytic converter -Z29- |
q | Removing and installing → Chapter |
q | 55 Nm |