audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Customer Interest:|871119|Page 3731 > < All Technical Service Bulletins for Power Distribution Module:|971015|Page 3725
Page 1
background image

Wiring Harness: Customer Interest
A/C - Blower Operates, System Does Not Cool/DTC's

87 Air conditioning inoperative

87 11 19 

2020124/4 

April 8, 2011. 

Supersedes Technical Service Bulletin Group 87 number 10 - 05 dated August 24, 2010 for reasons listed below.

AFFECTED VEHICLES

CONDITION 
Air conditioning is inoperative.

The HVAC blower functions normally.

Battery discharged, however, when charged, there is no bus silence when vehicle ignition is off.

TECHNICAL BACKGROUND

^ The A/C Pressure/Temperature Sensor G395 leaks refrigerant. This causes Sensor G395 to show an incorrect or implausible value when reading

MVBs. An incorrect signal or a low refrigerant level in the system can cause the air conditioning compressor to deactivate.

^ The LIN cable connecting the J519 Central Electrics Control unit to Sensor G395 is pinched or cut. This affects the A4/S4, A5/S5 Coupe and

Cabriolet, and Audi Q5 vehicles. The A6 and A8 are not affected by this type of failure.

^ The pressure sensor G395/G65 sends an incorrect signal that prevents bus silence and the battery is discharged.

Tip: Sensor G395 is a LIN slave of Vehicle Electrical System Control Module J519. Vehicle Electrical System Control Module J519 transfers the
information provided by the sensor via the comfort data bus to Climate Control Module J255.

PRODUCTION SOLUTION 

An improved A/C Pressure/Temperature Sensor G395 was introduced into series production and the wiring manufacturer's processes were optimized.

Customer Interest:|871119|Page 3731 > < All Technical Service Bulletins for Power Distribution Module:|971015|Page 3725