PRODUCTION SOLUTION

Hardware or software improvements

SERVICE

1. Connect a recommended battery charger to the designated charging posts in the vehicle.

Tip: To avoid false readings of the battery manager, don't charge the battery directly at its posts.

2. Disconnect the optical connection of the CD changer R-41. Install the flat contact housing (MOST loop) 4E0 973 802.

^ If the symptom disappears, replace the CD changer.

^ If the symptom remains, reconnect the optical connection of the CD changer and proceed to step 3.

3. Disconnect the optical connection of the Audi Music Interface (if applicable). Install the flat contact housing (MOST loop) 4E0 973 802.

^ If the symptom disappears, replace the control module.

^ If the symptom still remains, reconnect the optical connection of the Audi Music Interface and proceed to step 4.

4. Disconnect the optical connection of the Telephone transceiver R-36 (if applicable). Install the flat contact housing (MOST loop) 4E0 973 802.

^ If the symptom disappears:

For MY 2007-2008:

1. Replace the control module with part number 4F0 910 336 H or HX and code it to 10900.

2. In the telephone transceiver, ensure that adaption value 133 is set to 1 and adaptation value 134 is set to 0.

3. Perform an MMI Software Update. Only CD#2 is required, since R-36 already has the necessary software with the prior installation of 4F0
910336 H or HX. Refer to Technical Service Bulletin 2019334 for directions to perform the update.

For MY 2009: Replace the control module.

^ If the symptom still remains, reconnect the optical connection of the Telephone transceiver and proceed to step 5.

5. Proceed to individually loop Radio Tuner, Navigation, SDARS Tuner, Amplifier and Gateway. (If you loop Gateway, you must push the on/off button
to turn the MMI on.). Remove speech input control module J507 and swap Headunit J523 until the malfunctioning component is identified. If the
symptom still remains, open a TAC ticket. 