background image

-

Clamp off coolant hoses - 1 and - 2 - with Hose Clamps Up to 25 mm dia. 3094.

-

Disconnect electrical connector - 4 -.

-

Remove nut - 3 -.

-

Place Drip Tray for VAS 6100 VAS 6208 below After-Run Coolant Pump V51.

-

Remove coolant hoses from After-Run Coolant Pump V51.

-

Remove After-Run Coolant Pump V51.

Installing

^

Tightening torque see Coolant pump and coolant thermostat, assembly overview.

Installation is in reverse order of removal, note the following:

Note: 
^

Secure all hose connections using hose clamps appropriate for the model type.

-

Fill with coolant.