A6 Quattro Sedan V8-4.2L (BVJ) (2007)
-
Clamp off coolant hoses - 1 and - 2 - with Hose Clamps Up to 25 mm dia. 3094.
-
Disconnect electrical connector - 4 -.
-
Remove nut - 3 -.
-
Place Drip Tray for VAS 6100 VAS 6208 below After-Run Coolant Pump V51.
-
Remove coolant hoses from After-Run Coolant Pump V51.
-
Remove After-Run Coolant Pump V51.
Installing
^
Tightening torque see Coolant pump and coolant thermostat, assembly overview.
Installation is in reverse order of removal, note the following:
Note:
^
Secure all hose connections using hose clamps appropriate for the model type.
-
Fill with coolant.