background image

-

Crank the engine.

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals 2 to 6 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was not obtained:

-

Replace Heated Oxygen Sensor (HO2S) (G39).

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Engine
Control Module/Service and Repair/Engine Control Module.

-

Using a Multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals to the Motronic Engine Control
Module (ECM) (J623) electrical harness connector T94a terminals for an open circuit. 