A6 Quattro Sedan V8-4.2L (BVJ) (2007)
-
Remove the coolant reservoir and disconnect the Engine Coolant Level (ECL) Warning Switch (F66) electrical harness connector.
-
Position the coolant reservoir aside with the coolant hoses - 1 through 3 - attached.
-
Disconnect the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector - 2 -.
Checking primary voltage
-
Switch the ignition on.
-
Using a multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector
terminals 3 to 4 for voltage.