A6 Quattro Sedan V8-4.2L (BVJ) (2007)
-
Disconnect electrical harness connector - arrow - at locking flange.
-
Connect Remote Control (V.A.G 1348/3A) with Adapter Cable (V.A.G 1348/3-3) with an adapter cable from Connector Test Set (V.A.G 1594C)
at terminal - 5 -.
-
Cover 2nd connector terminal of Adapter Cable (V.A.G 1348/3-3) with insulating tape to prevent short circuit - arrow -.
-
Route Remote Control (V.A.G 1348/3A) switch forward in engine compartment.
-
Connect alligator clip to Ground (GND) point in engine compartment.
-
Connect the contact - 1 - to the vehicle battery (+) with an adapter cable created for this. For safety reasons, install a fuse - A - (10 A) in the wiring
connection.
-
Remove fuel filler cap from fuel filler tube.
-
Remove rear engine cover.
CAUTION!