A6 Quattro Wagon V6-2.8L (AFC) (1995)
Output Shaft: Service and Repair
Automatic Transmission 01F
Transmission Installed
Remove exhaust pipe with three way catalytic converters (arrows -2-)
-
Remove front crossmember (arrow -1-) and heat shield.
-
Detach driveshaft at transmission.
Do not lower driveshaft more than necessary to remove flanged shaft.
-
Secure driveshaft at exhaust pipe to prevent it falling down.
CAUTION! If the driveshaft is not correctly installed, the joints will be damaged.
-
Place oil tray below end cover.
-
Remove circlip -A-.
-
Thread M8 bolt into tapped hole of cap -B- and remove cap together with magnet.
Note: Always replace 0-ring.
-
Remove flanged shaft by pulling circlip apart: pry out flanged shaft with assembly lever, if necessary.