A6 Sedan V6-2.8L (AHA) (1998)
^
Subtract 935 from the numerical value in field 4 (example 34231 - 935 = 33296 +/- 5); this will become your calibration value
^
Move drivers seatback towards sitting position until numerical value in Field 4 equals the calibration value
^
Press --> button
^
Press buttons -0- and -4- to select "Basic Setting" function 04
^
Press -Q- button to confirm
^
Press buttons -0-, -0- and -1-
^
Press -Q- button to confirm
^
The display should show "Basic Value Learned"
^
Press --> button
^
Recheck current numerical value in measuring block 2
^
Press buttons -0- and -8- to select "Read Measuring Value Block" function 08
^
Press -Q- button
^
Press -0-, -0- and -2- buttons
^
Press -Q- to confirm
^
Indicated on the display (example values) must be the average numerical value (32767) in Field 4
^
Press --> button and remove VAG 1551 from the vehicle
^
Proceed to Section D
Section D- Learning position of seatback, mechanical check
^
Move drivers seatback fully rearward
^
Press memory button (arrow) and one memory location button simultaneously (e.g., P1, P2, P3)