‹› Do not crimp the wire insulation.
After crimping, crimp connections must be heat shrunk using hot air gun to prevent moisture penetration.
-
Place the (VAS 1978/15A) on the (VAS 1978/14A).
CAUTION!
Risk of damaging surrounding components.
‹› When heat-shrinking crimp connections, be careful not to damage any other wiring, plastic parts or insulating material with the hot
nozzle of the hot air blower.
‹› Always observe operating instructions of heat gun.
-
Heat the crimp connection using the hot air blower lengthwise from center outward until it is sealed completely and adhesive comes out the ends.