audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service and Repair
Page 2
background image

NOTE:  Moisten O-ring seals slightly with refrigerant oil before fitting.

-

Insert the two refrigerant pipes -B- and -C- in accumulator such that they are not strained. In doing so, pay attention to correct assignment of
connections.

-

Insert bolts -D- and tighten to 10 Nm.

-

Use bolt -A- (tightening torque 10 Nm) to attach refrigerant pipe to accumulator.

-

Re-install remaining components removed.

-

Evacuate and re-charge refrigerant circuit.

Air Door, HVAC > < Accumulator HVAC|Service and Repair