Compressor Pulley: Adjustments

Drive Plate with Overload Protection, Checking Run-Out and Adjusting

-

Remove compressor. Refer to => [ Compressor, S8 10 Cylinder ] See: Service and Repair. 

-

Clean flange at drive plate - A -

-

Secure a dial gauge - B - using a dial gauge holder -  C - using Dial Gauge Holder (Vw 387)on compressor.

-

Set probe of dial gauge - D - on flange of drive plate - A - with a pre-tension of approximately 1.0 mm.

-

Turn compressor drive unit - E - several rotations. 

Specification: Run-out deviation is less than 0.21 mm run-out of dial indicator, difference between smallest and largest measured value 0.2 mm
maximum 

-

If run-out deviation is greater than 0.2 mm, loosen bolts on drive plate. Refer to => [ Drive Plate with Overload Protection ] See: Service and
Repair/Drive Plate With Overload Protection and re-adjust drive plate.