Disconnect the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 -.
Checking internal resistance
-
Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) terminals 3 to 4 for resistance.
Specified value: 2.5 to 10.0 ohms (at approx. 20 °C)
If the specification was not obtained: