A8 Sedan V8-3.7L (AEW) (1997)
Maintenance Required Lamp/Indicator: Service and Repair
Channel 08 (Inspection 2 Service Interval Value - Time/Days)
SRI, inspection indicator (In 2), resetting (time)
Initiate Adaption Function.
-
Press button -0- and -8- to select channel 8.
-
Press -Q- button to confirm input.
Channel 8 Adaptation 66 ->
<-13->
- Advance through program sequence with -> button.
Channel 8 Adaptation 66 Q
Input adaptation value XXXXX
- Enter Adaptation value between 0 days (00000) and 730 days (00073). The value can be entered in steps of 10 days. Example: 730 days, therefore
enter 00073.
-
Press -Q- button to confirm input.
Channel B Adaptation 73 Q
Store changed value?
-
Press -Q- button to confirm input.
Channel 8 Adaptation 73 Q
Changed value stored
-
Press button to end coding.
Rapid data transfer HELP
Select function XX
-
Press buttons -1- and -0- to select "Adaptation" function 10.
Rapid data transfer Q
10 - Adaptation
-
Press -Q- button to confirm input.
Adaptation
Insert channel number XX