A8L V8-4.2L (BFM) (2004)
-
Carefully release and disconnect electrical harness connector -2- on right connector flange.
-
Connect multimeter between terminal 2 and 3 on connector -A- for resistance measurement.
-
For measured value 0 Ohms there is a short circuit, for measured value an open circuit.
NOTE: To check resistance values "tank full" or "tank empty", Fuel Supply Sensor 4 -G393- must be removed and the sensor floater must be
placed in upper or lower end position.