audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 7306 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 7304
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor Heater Before Catalytic Converter, Checking

Diagnostic Procedures

Oxygen Sensor Heaters Before Catalytic Converter, Checking

‹› When servicing terminals in harness connector of oxygen sensors, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Hand multimeter (V.A.G 1526) or Multimeter (V.A.G 1715)

‹› Test adapter kit (V.A.G 1594)

‹› Wiring diagram

Test conditions

‹›  Motronic Engine Control Module (ECM) Power Supply Relay 2 (J670) must be OK, checking: 

‹› Battery voltage (both batteries) must be at least 11.5 Volts.

‹› All electrical consumers such as, lights and rear window defroster must be switched off.

‹› For vehicles with automatic transmission, selector lever must be in " P".

‹› Parking brake must be engaged.

‹› The Ground (GND) connections between engine and body must be OK.

‹› Ignition switched off.

‹› Fuses in right instrument panel fuse holder must be OK: 

Right instrument panel fuse holder

Voltage Supply and Wiring to Control Module, Checking 

Test sequence

-

Disconnect corresponding 6-pin harness connector to oxygen sensor to be tested: Component location 

-

Connect multimeter to terminals 3 +4 of connector to Engine Control Module for voltage measurement.

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 7306 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 7304