Oxygen Sensor: Testing and Inspection
Oxygen Sensors and Oxygen Sensor Regulation After Catalytic Converter,Checking

Diagnostic Procedures

Oxygen Sensors and Oxygen Sensor Regulation after Catalytic Converter, Checking

‹› When servicing terminals 3 and 4 in harness connector of oxygen sensors, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Hand multimeter (V.A.G 1526) or Multimeter (V.A.G 1715)

‹› Test adapter kit (V.A.G 1594)

‹› Wiring diagram

Test Conditions

‹›  Motronic Engine Control Module (ECM) Power Supply Relay (J271) -position 4- must be OK, check: 

‹› Battery voltage (both batteries) must be at least 11.5 Volts.

‹› All electrical consumers such as, lights and rear window defroster must be switched off.

‹› For vehicles with automatic transmission, selector lever must be in " P".

‹› Parking brake must be engaged.

‹› The Ground (GND) connections between engine and body must be OK.

‹› Exhaust system must be properly sealed between catalytic converter and cylinder head.

‹› Coolant temperature must be at least 80 °C => See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and

Procedures/Diagnostic Modes 01 - 09/Diagnostic Mode 01 - Read Current System Data, Diagnostic mode 1: Check measured values; PID 5,
Coolant temperature.

‹› Oxygen sensor heaters for oxygen sensors behind catalytic converter must be OK, checking => [ Oxygen Sensor Heaters After Catalytic

Converter, Checking ].

‹› Fuses in right instrument panel fuse holder must be OK: 

Right instrument panel fuse holder

Function Test

-

Select oxygen sensor test results and check whether specified values are being reached =>See: Computers and Control Systems/Testing and

Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 6451 > < Oxygen Sensor Heaters After Catalytic Converter, Checking|Page 6449