Q5 Quattro V6-3.2L (CALB) (2009)
‹› This information for adjusting the calibration device is important for later steps in the procedure to avoid malfunctions.
-
Secure lane change assistance calibration device (VAS 6350/4 ) at left rear of Calibration Device (VAS 6350 ) mount.
‹› When installed correctly, vehicle electrical system voltage line must be connected at bottom left of calibration device (as seen in direction of
travel).
‹› Dimension - a - = 660 mm (measured from upper edge of calibration device to floor).
-
The indicator on the base of the lane change assistance calibration device (VAS 6350/4) must align with setting on measurement scale - 1 - on
measuring field - arrow -.
‹› Left setting = 703 mm (read on measurement scale - 1 -).
-
Connect lane change assistance calibration device (VAS 6350/4 ) to vehicle electrical system voltage.
-
Bring Calibration Device (VAS 6350) into horizontal position by turning plastic base.