‹› This information for adjusting the calibration device is important for later steps in the procedure to avoid malfunctions.

-

Secure lane change assistance calibration device (VAS 6350/4 ) at left rear of Calibration Device (VAS 6350 ) mount.

‹› When installed correctly, vehicle electrical system voltage line must be connected at bottom left of calibration device (as seen in direction of

travel).

‹› Dimension - a - = 660 mm (measured from upper edge of calibration device to floor).

-

The indicator on the base of the lane change assistance calibration device (VAS 6350/4) must align with setting on measurement scale - 1 - on
measuring field - arrow -.

‹› Left setting = 703 mm (read on measurement scale - 1 -). 

-

Connect lane change assistance calibration device (VAS 6350/4 ) to vehicle electrical system voltage.

-

Bring Calibration Device (VAS 6350) into horizontal position by turning plastic base.