audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Refrigerant Lines with Inner Heat Exchanger|Page 2511 > < Refrigerant Lines with Inner Heat Exchanger|Page 2509
Page 3
background image

-

Check the connections in the expansion valve - B - and on the refrigerant line - D - for damage.

-

Replace the quick acting coupling connectors on the refrigerant line with inner heat exchanger. Refer to => [ Refrigerant Line Quick Release
Couplings, Disconnecting and Connecting ] See: Heating and Air Conditioning/Coupler HVAC/Service and Repair/Refrigerant Line Quick
Release Couplings, Disconnecting and Connecting. 

-

Replace the O-ring seals - A - and - C -.

‹› Note the installation instructions for O-ring seals. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Heating and Air Conditioning/Service and

Repair/Removal and Replacement/Refrigerant Circuit O-ring Seals.

-

Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-ring Seals ] See: Heating and Air
Conditioning/Service and Repair/Removal and Replacement/Refrigerant Circuit O-ring Seals.

-

Make sure the O-ring seals fit properly in the refrigerant line connection grooves and on the refrigerant line - D -.

-

Tighten the bolts - E - for the refrigerant line -  D - with inner heat exchanger.

‹› Tightening specification for the bolts - E -: 10 Nm. 

-

Tighten the nut - C - for the refrigerant line -  B -.

Refrigerant Lines with Inner Heat Exchanger|Page 2511 > < Refrigerant Lines with Inner Heat Exchanger|Page 2509